Alarm Description

A non-monotonic arc was found in a PQ block. This will occur in PQ blocks within a G71 or G72 if the arc changes its X or Z direction. Increasing the arc radius will often correct this problem.

This information is for reference only. Haas is a registered trademark and the original is the property of Haas Automation, Inc.

Help the CNC Community: How Did You Fix It?

If you have encountered this Haas Alarm 604 NON-MONOTONOUS ARC IN PQ BLOCK – Haas Lathe error code before or know a proven troubleshooting step to resolve it, please share your solution in the comments below.