Haas Alarm: 125 SHUTTLE FAULT – Mill

Haas Alarm 125 SHUTTLE FAULT – Haas Mill

Alarm Description

Tool shuttle not initialized at power on, Cycle Start, or spindle motion command. This means that the tool shuttle was not fully retracted to the Out position. The shuttle In/Out switches may not be functioning normally. This alarm can be caused by anything that jams the motion of the slide, a loss of power to the tool changer. Check the shuttle arm clutch for wear. Check shuttle motor for rotation. Check motor brushes and test for power at motor. Check relays K9-K12 on and fuse F1 on I/O PCB.

This information is for reference only. Haas is a registered trademark and the original is the property of Haas Automation, Inc.

Help the CNC Community: How Did You Fix It?

If you have encountered this Haas Alarm 125 SHUTTLE FAULT – Haas Mill error code before or know a proven troubleshooting step to resolve it, please share your solution in the comments below.

Leave a Reply

Your email address will not be published. Required fields are marked *