Haas Alarm: 101 COMM. FAILURE WITH MOCON/MOCON MEMORY FAULT

Haas Alarm 101 COMM. FAILURE WITH MOCON/MOCON MEMORY FAULT

Alarm Description

During self-test of communications between MOCON and main processor, the main processor does not respond, and one of them is possibly bad. Check cable connections and boards. Re-seat or replace ADDRESS and DATA bus cables. This may also be caused by a memory fault detected on the MOCON. Check MOCON/PROCESSOR Status Lights. Verify correct power to MOCON