Fanuc Alarm: 5046 ILLEGAL PARAMETER (ST.COMP)

Fanuc Alarm 5046 ILLEGAL PARAMETER (ST.COMP)

Fanus Control Model: 16/18/21, 16i/18i/21i

Alarm Description

The parameter settings for straightness compensation contain an error. Possible causes are as follows;1. A parameter for a movement axis or compensation axis contains an axis number which is not used.;2. More than 128 pitch error compensation points exist between the negative and positive end points.;3. Compensation point numbers for straightness compensation are not assigned in the correct order.;4. No straightness compensation point exists between the pitch error compensation points at the negative and positive ends.;5. The compensation value for each compensation point is too large or too small.

Help the CNC Community: How Did You Fix It?

If you have encountered this Fanuc Alarm 5046 ILLEGAL PARAMETER (ST.COMP) error code before or know a proven troubleshooting step to resolve it, please share your solution in the comments below