Fanuc Alarm 38: INTERFERENCE IN CIRCULAR BLOCK

Fanuc Alarm 38: INTERFERENCE IN CIRCULAR BLOCK Fanus Control Model: 16/18/21, 16i/18i/21i Alarm Description Overcutting will occur in tool radius/tool nose radius/cutter compensation because the arc start point or end point coincides with the arc center. Modify the program. Help…

Fanuc Alarm 33: NO SOLUTION AT CRC

Fanuc Alarm 33: NO SOLUTION AT CRC Fanus Control Model: 16/18/21, 16i/18i/21i Alarm Description M Series: A point of intersection cannot be determined for cutter compensation C. Modify the program. T Series: A point of intersection cannot be determined for…

Fanuc Alarm 30: ILLEGAL OFFSET NUMBER

Fanuc Alarm 30: ILLEGAL OFFSET NUMBER Fanus Control Model: 16/18/21, 16i/18i/21i Alarm Description M Series;The offset values specified by D/H code for tool length offset, cutter compensation or 3–dimensional cutter compensation is too large. Otherwise, the number specified by P…

Fanuc Alarm 29: ILLEGAL OFFSET VALUE

Fanuc Alarm 29: ILLEGAL OFFSET VALUE Fanus Control Model: 16/18/21, 16i/18i/21i Alarm Description M Series;The offset values specified by H code is too large. Modify the program. Help the CNC Community: How Did You Fix It? If you have encountered…

Fanuc Alarm 36: CAN NOT COMMANDED G31

Fanuc Alarm 36: CAN NOT COMMANDED G31 Fanus Control Model: 16/18/21, 16i/18i/21i Alarm Description Skip cutting (G31) was specified in cutter compensation mode. Modify the program. Help the CNC Community: How Did You Fix It? If you have encountered this…