Haas Alarm 101 COMM. FAILURE WITH MOCON/MOCON MEMORY FAULT
Alarm Description
During self-test of communications between MOCON and main processor, the main processor does not respond, and one of them is possibly bad. Check cable connections and boards. Re-seat or replace ADDRESS and DATA bus cables. This may also be caused by a memory fault detected on the MOCON. Check MOCON/PROCESSOR Status Lights. Verify correct power to MOCON
This information is for reference only. Haas is a registered trademark and the original is the property of Haas Automation, Inc.
Help the CNC Community: How Did You Fix It?
If you have encountered this Haas Alarm 101 COMM. FAILURE WITH MOCON/MOCON MEMORY FAULT error code before or know a proven troubleshooting step to resolve it, please share your solution in the comments below.