Haas Alarm 113 SHUTTLE IN FAULT – Haas Mill
Alarm Description
Tool changer is not completely to the right. During tool changer operation, the tool in/out shuttle failed to get to the in position. Parameters 62 and 63 can adjust the time-out times. Verify parameters 62 and 63 are set to Haas specifications. This alarm can be caused by anything that jams the motion of the slide, the presence of a tool in the pocket facing the spindle, incorrect spindle orientation or a loss of power to the tool changer. Check relays K9-K12 and fuse F1 on I/O PCB. Check the shuttle arm clutch for wear. Check shuttle motor for rotation during tool change. Check motor brushes and test for power at motor.
This information is for reference only. Haas is a registered trademark and the original is the property of Haas Automation, Inc.
Help the CNC Community: How Did You Fix It?